TFIX-8S Universal Facade Fixing

Versatile screw-in facade fixing with high performance in all base materials recommended for ETICS

Features and benefits

  • Quick and easy installation in all substrates (categories A,B,C,D,E)
  • Unique sleeve compression zone for precision installations.
  • The long plastic overmoulding on the TFIX-8S screw minimises thermal bridging (value 0.002W/K), contributing to energy-saving benefits
  • Plate stiffness (value 0.6 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Pre-assembled screw saves time and labour.
  • Unique design allows for high load-bearing capacities. This reduces the quantity of fixings required per square metre of insulation
  • The shortest embedment depth at the maximum strength parameters

Contact us to get information about product availability and it’s price

Something went wrong... Please try again.

There is no store in the given location.

    Fill in the form with your details and send request for a TFIX-8S Universal Facade Fixing

    Your request will be sent to our sales department. Please note this is not a purchase order.
    See our Privacy and Security Policy. and Terms and Conditions of Product Request.

    Product information

    Size

    Product Code

    Fixing

    Fixture

    Diameter

    Length

    Plate diameter

    Recommended thickness

    d

    L

    D

    tfix A, B, C, D

    tfix E

    [mm]

    Ø08

    TFIX-8S-115

    8

    115

    60

    80

    40

    TFIX-8S-135

    8

    135

    60

    100

    60

    TFIX-8S-155

    8

    155

    60

    120

    80

    TFIX-8S-175

    8

    175

    60

    140

    100

    TFIX-8S-195

    8

    195

    60

    160

    120

    TFIX-8S-215

    8

    215

    60

    180

    140

    TFIX-8S-235

    8

    235

    60

    200

    160

    TFIX-8S-255

    8

    255

    60

    220

    180

    TFIX-8S-275

    8

    275

    60

    240

    200

    TFIX-8S-295

    8

    295

    60

    260

    220

    TFIX-8S-335

    8

    335

    60

    300

    260

    TFIX-8S-355

    8

    355

    60

    320

    280

    TFIX-8S-375

    8

    375

    60

    340

    300

    TFIX-8S-395

    8

    395

    60

    360

    320

    TFIX-8S-415

    8

    415

    60

    380

    340

    TFIX-8S-435

    8

    435

    60

    400

    360

    TFIX-8S-455

    8

    455

    60

    420

    380

    Base material

    • Concrete C12/15-C50/60 (Use category A)

      Concrete C12/15-C50/60 (Use category A)

    • Solid Brick (Use category B)

      Solid Brick (Use category B)

    • Solid Sand-lime Brick (Use category B)

      Solid Sand-lime Brick (Use category B)

    • Hollow Brick (Use category C)

      Hollow Brick (Use category C)

    • Hollow Sand-lime Brick (Use category C)

      Hollow Sand-lime Brick (Use category C)

    • Vertically-perforated clay block (Use category C)

      Vertically-perforated clay block (Use category C)

    • Lightweight Concrete Block (Use category C)

      Lightweight Concrete Block (Use category C)

    • Hollow Lightweight Concrete Block (Use category D)

      Hollow Lightweight Concrete Block (Use category D)

    • Reinforced components of lightweight aggregate concrete (Use category D)

      Reinforced components of lightweight aggregate concrete (Use category D)

    • Aerated Concrete Block (Use category D)

      Aerated Concrete Block (Use category D)

    Applications

    • External Thermal Insulation Composite Systems (ETICS)
    • Polystyrene (EPS) boards
    • Mineral wool (MW) boards
    • Light wood wool building boards
    • Polyurethane (PU) boards
    • Cork boards

    Installation guide

    Installation guide
    Installation guide
    Installation guide
    Installation guide
    Installation guide
    Installation guide
    1. Drill a hole of required diameter and depth
    2. Drilling depth of min 40mm in A,B,C,D materials and 80mm in Aerated Concrete Block
    3. Lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached
    4. Embedment depth of min 25mm in A,B,C,D materials and 65mm in Aerated Concrete Block
    5. Tighten screw (ideally using special TFIX-8S-TOOL setting tool) until fixing is secure and flush with insulation material.
    6. In soft insulation panels the fixing should be combined with insulation retaining plates KWL-90, KWL-110, KWL-140.

    Installation data

    Substrate

    A, B, C, D

    E

    Fixing diameter

    d

    [mm]

    8

    8

    Hole diameter in substrate

    d0

    [mm]

    8

    8

    Min. hole depth in substrate

    h0

    [mm]

    40

    80

    Min. installation depth

    hnom

    [mm]

    25

    65

    Min. substrate thickness

    hmin

    [mm]

    100

    100

    Min. spacing

    smin

    [mm]

    100

    100

    Min. edge distance

    cmin

    [mm]

    100

    100

    Downloads

    Need documents for other product? Visit our Technical Library.

    go to library

    Associated products

    • RT-SDSA Drill bits Aggressor SDS plus

      RT-SDSA Drill bits Aggressor SDS plus

    • RT-SDSB Drill bits Brickdrill SDS plus

      RT-SDSB Drill bits Brickdrill SDS plus

    • RT-SDSR Drill bits Rebardrill SDS plus

      RT-SDSR Drill bits Rebardrill SDS plus

    • KWL Insulation retaining plate

      KWL Insulation retaining plate

    • R-TFIX-8S Universal facade fixings

      R-TFIX-8S Universal facade fixings

    • TFIX-8S-TOOL Setting tool

      TFIX-8S-TOOL Setting tool

    Go to top