Something went wrong... Please try again.
R-HPTII-A4 Stainless Steel Throughbolt
Stainless steel throughbolt anchor for cracked and non-cracked concrete
Become a Rawlplug expert
ENTER THE COMPETITIONFeatures and benefits
- Stainless steel anchor for the highest corrosion resistance
- High performance in cracked and non-cracked concrete confirmed by ETA Option 1
- Highest quality ensures maximum load capability
- For applications requiring fire resistance up to 120 minutes
- Suitable for reduced embedment to avoid contact with reinforcement
- Embedment depth markings help to ensure precise installation of the anchor
- Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time
- Suitable for installation in corrosive environments category C1, C2, C3,C4 and C5
Contact us to get information about product availability and it’s price
Fill in the form with your details and send request for a R-HPTII-A4 Stainless Steel Throughbolt
Your request will be sent to our sales department. Please note this is not a purchase order.Product information
Size |
Product Code |
Anchor |
Fixture |
|||
Diameter |
Length |
Max. thickness tfix for: |
Hole diameter |
|||
d |
L |
hnom,red |
hnom,std |
df |
||
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
||
M8 |
R-HPTIIA4-08060/10 |
8 |
60 |
10 |
- |
9 |
R-HPTIIA4-08075/10 |
8 |
75 |
25 |
10 |
9 |
|
R-HPTIIA4-08085/20 |
8 |
85 |
35 |
20 |
9 |
|
R-HPTIIA4-08095/30 |
8 |
95 |
45 |
30 |
9 |
|
R-HPTIIA4-08105/40 |
8 |
105 |
55 |
40 |
9 |
|
R-HPTIIA4-08115/50 |
8 |
115 |
65 |
50 |
9 |
|
M10 |
R-HPTIIA4-10065/5 |
10 |
65 |
5 |
- |
11 |
R-HPTIIA4-10080/20 |
10 |
80 |
20 |
- |
11 |
|
R-HPTIIA4-10095/15 |
10 |
95 |
35 |
15 |
11 |
|
R-HPTIIA4-10115/35 |
10 |
115 |
55 |
35 |
11 |
|
R-HPTIIA4-10130/50 |
10 |
130 |
70 |
50 |
11 |
|
R-HPTIIA4-10140/60 |
10 |
140 |
80 |
60 |
11 |
|
M12 |
R-HPTIIA4-12080/5 |
12 |
80 |
5 |
- |
13 |
R-HPTIIA4-12100/5 |
12 |
100 |
25 |
5 |
13 |
|
R-HPTIIA4-12115/20 |
12 |
115 |
40 |
20 |
13 |
|
R-HPTIIA4-12125/30 |
12 |
125 |
50 |
30 |
13 |
|
R-HPTIIA4-12150/55 |
12 |
150 |
75 |
55 |
13 |
|
R-HPTIIA4-12180/85 |
12 |
180 |
105 |
85 |
13 |
|
M16 |
R-HPTIIA4-16125/5 |
16 |
125 |
25 |
5 |
18 |
R-HPTIIA4-16140/20 |
16 |
140 |
40 |
20 |
18 |
|
R-HPTIIA4-16150/30 |
16 |
150 |
50 |
30 |
18 |
|
R-HPTIIA4-16180/60 |
16 |
180 |
80 |
60 |
18 |
Base material
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Reinforced concrete
-
Unreinforced concrete
For use also with
-
Natural Stone (after site testing)
Applications
- Cladding restraints
- Barriers
- Structural steel
- Curtain walling
- Handrails
- Heavy Plant
- Balustrading
- Passenger lifts
- Facades
- Fencing & gates manufacturing and installation
- Masonry support
- Platforms
- Public seating
- Racking systems
Installation guide





- Drill a hole of required diameter and depth
- Clear the hole of drilling dust and debris (using blowpump or equivalent method)
- Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached
- Tighten to the recommended torque
Installation data
Size |
M8 |
M10 |
M12 |
M16 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
8 |
10 |
12 |
16 |
Installation torque |
Tinst |
[Nm] |
15 |
30 |
50 |
100 |
Wrench size |
Sw |
[mm] |
13 |
17 |
19 |
24 |
External diameter of washer |
[mm] |
16 |
20 |
24 |
30 |
|
STANDARD EMBEDMENT DEPTH | ||||||
Min. hole depth in substrate |
h0,s |
[mm] |
65 |
80 |
90 |
110 |
Min. installation depth |
hnom,s |
[mm] |
55 |
69 |
80 |
100 |
Min. substrate thickness |
hmin,s |
[mm] |
100 |
120 |
140 |
170 |
Min. spacing (Non-cracked concrete) |
smin, s |
[mm] |
55 |
70 |
90 |
135 |
Min. spacing (Cracked concrete) |
smin, s |
[mm] |
55 |
70 |
90 |
135 |
Min. edge distance (Non-cracked concrete) |
cmin, s |
[mm] |
40 |
50 |
55 |
80 |
Min. edge distance (Cracked concrete) |
cmin, s |
[mm] |
40 |
45 |
55 |
70 |
REDUCED EMBEDMENT DEPTH | ||||||
Min. hole depth in substrate |
h0,r |
[mm] |
50 |
60 |
70 |
90 |
Min. installation depth |
hnom,r |
[mm] |
40 |
49 |
60 |
80 |
Min. substrate thickness |
hmin,r |
[mm] |
100 |
100 |
100 |
130 |
Min. spacing (Non-cracked concrete) |
smin,r |
[mm] |
50 |
70 |
120 |
150 |
Min. spacing (Cracked concrete) |
smin,r |
[mm] |
50 |
70 |
120 |
150 |
Min. edge distance (Non-cracked concrete) |
cmin,r |
[mm] |
50 |
60 |
70 |
90 |
Min. edge distance (Cracked concrete) |
cmin,r |
[mm] |
40 |
50 |
70 |
85 |