KI-10N Long expansion zone facade fixing with metal pin

Hammer-in facade fixing 60mm long expansion zone for high performance in masonry, as well as lightweight and aerated concrete

Features and benefits

  • Easy installation with best performance in lightweight base materials
  • Approved for use in base material categories B, C, D, and E
  • Steel nail allows fast and trouble-free installation with correct expansion of the plug.
  • Reduction of thermal bridge formation (value 0.3W/K) through the integration of an impact-resistant plastic overmoulding on the nail head.
  • Plate stiffness (value 0.5 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Can be used with additional KWL insulation holding plate, available in 90, 110 and 140mm flange sizes.

Contact us to get information about product availability and it’s price

Something went wrong... Please try again.

There is no store in the given location.

    Fill in the form with your details and send request for a KI-10N Long expansion zone facade fixing with metal pin

    Your request will be sent to our sales department. Please note this is not a purchase order.
    See our Privacy and Security Policy. and Terms and Conditions of Product Request.

    Product information

    Size

    Product Code

    Fixing

    Fixture

    Diameter

    Length

    Plate diameter

    Recommended thickness

    d

    L

    D

    tfix B, C, D, E

    [mm]

    Ø10

    KI-140N

    10

    140

    60

    70

    KI-160N

    10

    160

    60

    90

    KI-180N

    10

    180

    60

    110

    KI-200N

    10

    200

    60

    130

    KI-220N

    10

    220

    60

    150

    KI-260N

    10

    260

    60

    190

    KI-300N

    10

    300

    60

    210

    Base material

    • Solid Brick (Use category B)

      Solid Brick (Use category B)

    • Hollow Brick (Use category C)

      Hollow Brick (Use category C)

    • Vertically-perforated clay block (Use category C)

      Vertically-perforated clay block (Use category C)

    • Lightweight Concrete Block (Use category C)

      Lightweight Concrete Block (Use category C)

    • Reinforced components of lightweight aggregate concrete (Use category D)

      Reinforced components of lightweight aggregate concrete (Use category D)

    • Aerated Concrete Block (Use category D)

      Aerated Concrete Block (Use category D)

    Applications

    • External Thermal Insulation Composite Systems (ETICS)
    • Polystyrene (EPS) boards
    • Mineral wool (MW) boards
    • Light wood wool building boards
    • Polyurethane (PU) boards
    • Lightweight recycled panels

    Installation guide

    Installation guide
    Installation guide
    Installation guide
    Installation guide
    Installation guide
    1. Drill a hole of required diameter and depth
    2. Drilling depth of min 80mm in approved materials.
    3. Lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached
    4. Embedment depth of min 60mm in approved materials.
    5. Hammer the steel nail into the plastic sleeve until fixing is secure and flush with insulation material.
    6. In soft insulation panels the fixing should be combined with insulation retaining plates KWL-90, KWL-110, KWL-140.
    7. Temperature range when installed -35C to +80C.

    Installation data

    Substrate

    B, C, D, E

    Fixing diameter

    d

    [mm]

    10

    Hole diameter in substrate

    d0

    [mm]

    10

    Min. hole depth in substrate

    h0

    [mm]

    70

    Min. installation depth

    hnom

    [mm]

    60

    Min. substrate thickness

    hmin

    [mm]

    100

    Min. spacing

    smin

    [mm]

    100

    Min. edge distance

    cmin

    [mm]

    100

    Associated products

    • KWL Insulation retaining plate

      KWL Insulation retaining plate

    Go to top