4ALL

High performance nylon plug for all types of substrates

Product photo
Features:
  • Unique internal design provides positive grip for screws.
  • Anti-rotational lugs promote grip in wide range of substrates including soft masonry materials.
  • Rib detail at plug head provides added grip.
  • Expanding section designed to collapse in hollow materials and provide positive grip behind surfaces.
  • Unique 4 way expansion allowing application in any substrate material and type.
  • Solid head design provides strength whilst plug is installed.
Product side photo

Size

Product Code

Plug

Quantity [pcs]

Weight [kg]

Bar Codes

Diameter [mm]

Box

Outer

Pallet

Box

Outer

Pallet

Ø05

4ALL-05

5

100

3200

179200

0.07

2.1

148.6

5906675028408

Ø06

4ALL-06

6

100

3200

179200

0.09

2.8

188.0

5906675028903

4ALL-06050

6

50

3200

76800

0.07

4.3

133.7

5906675383477

Ø08

4ALL-08

8

100

1600

89600

0.21

3.4

217.7

5906675028910

4ALL-08065

8

50

1600

38400

0.15

4.7

142.9

5906675383484

Ø10

4ALL-10

10

50

800

44800

0.19

3.1

200.5

5906675028927

Ø12

4ALL-12

12

20

320

17920

0.14

2.3

157.2

5906675159454

Ø14

4ALL-14

14

10

160

8960

0.12

1.94

138.9

5906675159478

Performance data for single fixing without influence of edge distance and spacing

SubstrateConcrete C20/25 - C50/60Solid clay brick min 20MPa (eg Mz20/2.0)Sand-lime solid brickPerforated brick 15MPaSand-lime hollow block min. 20MPaAerated concrete 600 Mark VPlasterboard min. 12.5 mmPlasterboard min. 2x12.5 mm
CHARACTERISTIC LOAD FRk
Ø5, Embedment depth 25mm[kN]0.10-0.200.150.500.200.11-
Ø6, Embedment depth 30mm[kN]0.200.150.600.300.600.300.12-
Ø8, Embedment depth 40mm[kN]0.500.750.900.500.750.500.15-
Ø10, Embedment depth 50mm[kN]0.500.901.200.500.750.600.26-
Ø12, Embedment depth 60mm[kN]4.504.007.002.504.503.50-0.66
Ø14, Embedment depth 70mm[kN]5.506.0010.501.505.005.50-0.74
DESIGN LOAD FRd
Ø5, Embedment depth 25mm[kN]0.06-0.080.060.200.100.06-
Ø6, Embedment depth 30mm[kN]0.110.060.240.120.240.150.06-
Ø8, Embedment depth 40mm[kN]0.280.300.360.200.300.250.08-
Ø10, Embedment depth 50mm[kN]0.280.360.480.200.300.300.13-
Ø12, Embedment depth 60mm[kN]2.501.602.801.001.801.75-0.33
Ø14, Embedment depth 70mm[kN]3.062.404.200.602.002.75-0.37
RECOMMENDED LOAD Frec
Ø5, Embedment depth 25mm[kN]0.04-0.060.040.140.070.04-
Ø6, Embedment depth 30mm[kN]0.080.040.170.090.170.110.04-
Ø8, Embedment depth 40mm[kN]0.200.210.260.140.210.180.05-
Ø10, Embedment depth 50mm[kN]0.200.260.340.140.210.210.09-
Ø12, Embedment depth 60mm[kN]1.791.142.000.711.291.25-0.24
Ø14, Embedment depth 70mm[kN]2.181.713.000.431.431.96-0.26

Installation guide

1. Drill a hole of required diameter.

2. Insert 4ALL plug into hole and tap home.

3. Insert screw of required diameter into plug through fixture and tighten.

Size

Ø5

Ø6

Ø8

Ø10

Ø12

Ø14

Fixing diameter

d

[mm]

5

6

8

10

12

14

Hole diameter in substrate

d0

[mm]

5

6

8

10

12

14

Min. hole depth in substrate

h0

[mm]

35

40

50

60

70

80

Installation depth

hnom

[mm]

25

30

40

50

60

70

Min. substrate thickness

hmin

[mm]

65

70

80

90

100

100

Min. spacing

smin

[mm]

25

30

40

50

60

70

Min. edge distance

cmin

[mm]

25

30

40

50

60

70

Technical Data Sheet (PDF, 861.8 KB)